{"id":1609,"date":"2026-02-12T18:02:18","date_gmt":"2026-02-12T18:02:18","guid":{"rendered":"https:\/\/enviroeye.net\/?page_id=1609"},"modified":"2026-02-12T18:09:11","modified_gmt":"2026-02-12T18:09:11","slug":"product","status":"publish","type":"page","link":"https:\/\/enviroeye.net\/?page_id=1609","title":{"rendered":"Product"},"content":{"rendered":"\n<p class=\"wp-block-coblocks-highlight\"><mark class=\"wp-block-coblocks-highlight__content\"><br>The EnviroEye Drain Guard System<\/mark><\/p>\n\n\n\n<h2 class=\"wp-block-heading has-custom-lineheight has-custom-letterspacing\" style=\"line-height:1.3;letter-spacing:0.3px;font-size:19px\"><br>Integrated detection and automated valve control for external floating roof drain lines.<\/h2>\n\n\n<p><span style=\"color: #f25d27;\" data-darkreader-inline-color=\"\"><strong><a href=\"https:\/\/enviroeye.net\/wp-content\/uploads\/2019\/02\/EnviroEye-LLC-pic-DGS-EFR_rain-conditions.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"169\" class=\"size-medium wp-image-269 alignright\" src=\"https:\/\/enviroeye.net\/wp-content\/uploads\/2019\/02\/EnviroEye-LLC-pic-DGS-EFR_rain-conditions-300x169.jpg\" alt=\"\" srcset=\"https:\/\/enviroeye.net\/wp-content\/uploads\/2019\/02\/EnviroEye-LLC-pic-DGS-EFR_rain-conditions-300x169.jpg 300w, https:\/\/enviroeye.net\/wp-content\/uploads\/2019\/02\/EnviroEye-LLC-pic-DGS-EFR_rain-conditions-768x432.jpg 768w, https:\/\/enviroeye.net\/wp-content\/uploads\/2019\/02\/EnviroEye-LLC-pic-DGS-EFR_rain-conditions-1024x576.jpg 1024w, https:\/\/enviroeye.net\/wp-content\/uploads\/2019\/02\/EnviroEye-LLC-pic-DGS-EFR_rain-conditions.jpg 1182w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a>Features and Benefits<\/strong><\/span><\/p>\n<p class=\"p1\">EnviroEye delivers continuous electronic hydrocarbon detection for floating roof drainage systems and automatically actuates protective response when preset thresholds are exceeded. By minimizing dependence on manual inspection and operator intervention, the system enables unattended operation while preserving controlled discharge and environmental compliance.<\/p>\n<p><span style=\"color: #f25d27;\" data-darkreader-inline-color=\"\"><strong>Safety Standards<\/strong><\/span><\/p>\n<p class=\"p1\">EnviroEye is engineered for operation in classified hazardous locations and configured in accordance with applicable industry safety standards. System components and protective enclosures are specified to support reliable performance in the operating conditions typical of petroleum storage and terminal facilities.<\/p>\n<p><span style=\"color: #f25d27;\" data-darkreader-inline-color=\"\"><strong>Set Up and Maintenance<\/strong><\/span><\/p>\n<p class=\"p1\">EnviroEye is externally mounted and integrates with existing drainage infrastructure via standard flanged connections. Installation typically involves positioning and leveling the unit on a concrete pad and can be performed without interrupting tank service.<\/p>\n<p class=\"p1\">Routine maintenance is limited and predictable. The system is designed to be incorporated into established inspection and preventive maintenance programs without creating additional operational complexity.<\/p>\n<p><a href=\"https:\/\/enviroeye.net\/wp-content\/uploads\/2015\/12\/EE-Schematic.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-48 aligncenter\" src=\"https:\/\/enviroeye.net\/wp-content\/uploads\/2015\/12\/EE-Schematic-300x96.jpg\" alt=\"EE Schematic\" width=\"597\" height=\"191\" srcset=\"https:\/\/enviroeye.net\/wp-content\/uploads\/2015\/12\/EE-Schematic-300x96.jpg 300w, https:\/\/enviroeye.net\/wp-content\/uploads\/2015\/12\/EE-Schematic-1024x328.jpg 1024w, https:\/\/enviroeye.net\/wp-content\/uploads\/2015\/12\/EE-Schematic-1800x576.jpg 1800w, https:\/\/enviroeye.net\/wp-content\/uploads\/2015\/12\/EE-Schematic.jpg 1840w\" sizes=\"auto, (max-width: 597px) 100vw, 597px\" \/><\/a><\/p>\n\n\n<p class=\"wp-block-paragraph\">Standard Options:<\/p>\n\n\n\n<div class=\"wp-block-coblocks-row coblocks-row-1111575516\" data-columns=\"2\" data-layout=\"50-50\"><div class=\"wp-block-coblocks-row__inner has-no-padding has-no-margin is-stacked-on-mobile has-medium-gutter\">\n<div class=\"wp-block-coblocks-column coblocks-column-11115758695\" style=\"width:50%\"><div class=\"wp-block-coblocks-column__inner has-no-padding has-no-margin\">\n<ul class=\"wp-block-list\">\n<li>Flow chamber with baffle and hydrocarbon sensor<\/li>\n\n\n\n<li>Motor-operated closure valve (MOV)<\/li>\n\n\n\n<li>Class I, Division 1 (C1D1) enclosure<\/li>\n\n\n\n<li>System test switch<\/li>\n\n\n\n<li>Milliamp reader for at-a-glance system health<\/li>\n\n\n\n<li>Local audible and\/or visual alarm<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-coblocks-column coblocks-column-11115758696\" style=\"width:50%\"><div class=\"wp-block-coblocks-column__inner has-no-padding has-no-margin\">\n<ul class=\"wp-block-list\">\n<li>Discrete status and alarm outputs for DCS\/SCADA integration<\/li>\n\n\n\n<li>Remote notification capability<\/li>\n\n\n\n<li>Manual override and lockout provisions<\/li>\n\n\n\n<li>Defined fail-safe operating behavior<\/li>\n\n\n\n<li>Magnetic scale capture assembly<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Custom Options<\/strong><\/p>\n\n\n\n<div class=\"wp-block-coblocks-row coblocks-row-111151249705\" data-columns=\"2\" data-layout=\"50-50\"><div class=\"wp-block-coblocks-row__inner has-no-padding has-no-margin is-stacked-on-mobile has-medium-gutter\">\n<div class=\"wp-block-coblocks-column coblocks-column-111151252857\" style=\"width:50%\"><div class=\"wp-block-coblocks-column__inner has-no-padding has-no-margin\">\n<ul class=\"wp-block-list\">\n<li><strong>Bypass manifold<\/strong> for maintenance, testing, or alternate flow routing<\/li>\n\n\n\n<li><strong>Discrete I\/O for DCS \/ SCADA integration<\/strong>, configured to match site control standards<\/li>\n\n\n\n<li><strong>Remote notification capability<\/strong> for unattended operation or off-hours monitoring<\/li>\n\n\n\n<li><strong>Secondary motor-operated valve (tight-tolerance isolation)<\/strong> for enhanced containment or redundancy<\/li>\n\n\n\n<li><strong>Battery backup (UPS)<\/strong> to support defined operation during power interruptions<\/li>\n<\/ul>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-coblocks-column coblocks-column-111151252865\" style=\"width:50%\"><div class=\"wp-block-coblocks-column__inner has-no-padding has-no-margin\">\n<ul class=\"wp-block-list\">\n<li><strong>Cold weather package<\/strong>, including integrated heating for reliable operation in low-temperature environments<\/li>\n\n\n\n<li><strong>Filter system<\/strong> for dike outfall service applications<\/li>\n\n\n\n<li><strong>Containment tray<\/strong> to manage localized drips or maintenance-related discharge<\/li>\n\n\n\n<li><strong>Flow meter<\/strong> for monitoring, documentation, or operational insight<\/li>\n\n\n\n<li><strong>Quick-connect test port<\/strong> to support system verification and maintenance without disrupting operation<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Alternate Uses<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Monitor liquid runoff from diked areas and retention ponds (secondary containment)<\/li>\n\n\n\n<li>Well Heads<\/li>\n\n\n\n<li>Sumps related to rail cars, truck racks, and dock lines<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Integrated detection and automated valve control for external floating roof drain lines. Features and Benefits EnviroEye delivers continuous electronic hydrocarbon detection for floating roof drainage systems and automatically actuates protective response when preset thresholds are exceeded. By minimizing dependence on manual inspection and operator intervention, the system enables unattended operation while preserving controlled discharge and environmental compliance. Safety Standards EnviroEye is engineered&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","footnotes":""},"class_list":["post-1609","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/enviroeye.net\/index.php?rest_route=\/wp\/v2\/pages\/1609","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enviroeye.net\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/enviroeye.net\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/enviroeye.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/enviroeye.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1609"}],"version-history":[{"count":2,"href":"https:\/\/enviroeye.net\/index.php?rest_route=\/wp\/v2\/pages\/1609\/revisions"}],"predecessor-version":[{"id":1612,"href":"https:\/\/enviroeye.net\/index.php?rest_route=\/wp\/v2\/pages\/1609\/revisions\/1612"}],"wp:attachment":[{"href":"https:\/\/enviroeye.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}